CVE-2026-9650: Schneider-Electric Easylogic T150 Firmware Security Vulnerability (CVSS 8.7)

CVE-2026-9650 is a high severity security vulnerability in Schneider-Electric Easylogic T150 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Last updated: Jul 14, 2026

Quick answer

Direct answer

CVE-2026-9650 is a high severity security vulnerability in Schneider-Electric Easylogic T150 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Risk scores

CVSS base score
8.7HIGH
EPSS probability
0.41%
Higher than 33 percent of all CVEs
CISA KEV
Not listed
CVSS metricWhat it means
Attack vector (AV:N)Network: reachable remotely
Attack complexity (AC:L)Low complexity
Attack requirements (AT:N)No attack requirements
Privileges required (PR:N)No privileges required
User interaction (UI:N)No user interaction
Confidentiality (VC:H)High confidentiality impact
Integrity (VI:N)No integrity impact
Availability (VA:N)No availability impact

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

About Schneider-Electric Easylogic T150 Firmware

CVE-2026-9650 affects Schneider-Electric Easylogic T150 Firmware, a product from Schneider-Electric. Before acting, confirm where Schneider-Electric Easylogic T150 Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.

What the flaw is

In plain terms: CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.

Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Affected versions and timeline

FieldDetail
ProductSchneider-Electric Easylogic T150 Firmware
Affected versionsEasylogic T150 Firmware before 11.06.32; Saitel Dp Firmware before 11.06.38
PublishedJun 25, 2026
Last modifiedJul 14, 2026
Added to CISA KEVNot listed
Assigning CNAcybersecurity@se.com

How to detect it

  • Inventory every instance of Schneider-Electric Easylogic T150 Firmware and record the running version against the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
  • Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.

How to fix it

  • Apply the fixed version of Schneider-Electric Easylogic T150 Firmware named in the vendor advisory.
  • If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
  • Rescan after the change to prove the exposure is gone, then close the ticket.

CTEM action plan

CTEM stageWhat to do for this CVE
ScopeAdd every business service that depends on Schneider-Electric Easylogic T150 Firmware to the current CTEM cycle.
DiscoverFind all instances, including shadow and cloud deployments, and record versions and exposure.
PrioritizeRank using EPSS and CVSS together with asset exposure and business impact.
ValidateConfirm the flaw is reachable and exploitable in your environment and that compensating controls work.
MobilizeAssign the fix to the asset owner with a due date matched to the priority, then verify closure.

CWE References

Technical References

Frequently asked questions

CVE-2026-9650 is a high severity security vulnerability in Schneider-Electric Easylogic T150 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

HIGH8.6
CVE-2026-9717
Schneider-Electric Powerlogic P7 Firmware

CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.

Jun 25, 2026
HIGH8.7
CVE-2026-9716
Schneider-Electric Powerlogic P7 Firmware

CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.

Jun 25, 2026
HIGH8.2
CVE-2026-6866
Schneider-Electric Ecostruxure Panel Server Pas400 Firmware

CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials.

May 12, 2026
HIGH7.2
CVE-2026-2273
Schneider-Electric Ecostruxure Automation Expert

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.

Mar 10, 2026
HIGH8.5
CVE-2025-11739
Schneider-Electric Ecostruxure Power Monitoring Expert

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

Mar 10, 2026
HIGH8.4
CVE-2025-13845
Schneider-Electric Ecostruxure Power Build - Rapsody

CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.

Jan 15, 2026
All Schneider-Electric CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-9650 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications