LearnCTEM.com, Best CTEM Learning Platform
CVE Intelligence Hub

CVE-2025-13845: Schneider-Electric Ecostruxure Power Build - Rapsody Use After Free (CVSS 8.4)

CVE-2025-13845 is a high severity use after free in Schneider-Electric Ecostruxure Power Build - Rapsody with a CVSS score of 8.4. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Last updated: Sep 3, 2026

Quick answer

Direct answer

CVE-2025-13845 is a high severity use after free in Schneider-Electric Ecostruxure Power Build - Rapsody with a CVSS score of 8.4. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Risk scores

CVSS base score
8.4HIGH
EPSS probability
0.35%
Higher than 27 percent of all CVEs
CISA KEV
Not listed
CVSS metricWhat it means
Attack vector (AV:L)Local access needed
Attack complexity (AC:L)Low complexity
Attack requirements (AT:N)No attack requirements
Privileges required (PR:N)No privileges required
User interaction (UI:A)Active user interaction
Confidentiality (VC:H)High confidentiality impact
Integrity (VI:H)High integrity impact
Availability (VA:H)High availability impact

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

About Schneider-Electric Ecostruxure Power Build - Rapsody

CVE-2025-13845 affects Schneider-Electric Ecostruxure Power Build - Rapsody, a product from Schneider-Electric. Before acting, confirm where Schneider-Electric Ecostruxure Power Build - Rapsody runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.

What the flaw is

In plain terms: CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.

The weakness class is Use After Free. Memory is used after it was released, which can lead to code execution.

Based on its CVSS vector, the flaw needs local or adjacent access, needs no login, and relies on a user taking an action. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Affected versions and timeline

FieldDetail
ProductSchneider-Electric Ecostruxure Power Build - Rapsody
Affected versionsEcostruxure Power Build - Rapsody up to and including 2.8.1.0300; Ecostruxure Power Build - Rapsody up to and including 2.8.2.0000; Ecostruxure Power Build - Rapsody up to and including 2.8.3.0100; Ecostruxure Power Build - Rapsody up to and including 2.8.4.0300; Ecostruxure Power Build - Rapsody up to and including 2.8.5.0200; Ecostruxure Power Build - Rapsody up to and including 2.8.7.0100; Ecostruxure Power Build - Rapsody up to and including 2.8.8.0100
PublishedJan 15, 2026
Last modifiedSep 3, 2026
Added to CISA KEVNot listed
Assigning CNAcybersecurity@se.com

How to detect it

  • Inventory every instance of Schneider-Electric Ecostruxure Power Build - Rapsody and record the running version against the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
  • Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.

How to fix it

  • Apply the fixed version of Schneider-Electric Ecostruxure Power Build - Rapsody named in the vendor advisory.
  • If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
  • Rescan after the change to prove the exposure is gone, then close the ticket.

CTEM action plan

CTEM stageWhat to do for this CVE
ScopeAdd every business service that depends on Schneider-Electric Ecostruxure Power Build - Rapsody to the current CTEM cycle.
DiscoverFind all instances, including shadow and cloud deployments, and record versions and exposure.
PrioritizeRank using EPSS and CVSS together with asset exposure and business impact.
ValidateConfirm the flaw is reachable and exploitable in your environment and that compensating controls work.
MobilizeAssign the fix to the asset owner with a due date matched to the priority, then verify closure.

CWE References

Technical References

Frequently asked questions

CVE-2025-13845 is a high severity use after free in Schneider-Electric Ecostruxure Power Build - Rapsody with a CVSS score of 8.4. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

HIGH8.6
CVE-2026-9717
Schneider-Electric Powerlogic P7 Firmware

CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.

Jun 25, 2026
HIGH8.7
CVE-2026-9716
Schneider-Electric Powerlogic P7 Firmware

CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.

Jun 25, 2026
HIGH8.7
CVE-2026-9650
Schneider-Electric Easylogic T150 Firmware

CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.

Jun 25, 2026
HIGH8.2
CVE-2026-6866
Schneider-Electric Ecostruxure Panel Server Pas400 Firmware

CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials.

May 12, 2026
HIGH7.2
CVE-2026-2273
Schneider-Electric Ecostruxure Automation Expert

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.

Mar 10, 2026
HIGH8.5
CVE-2025-11739
Schneider-Electric Ecostruxure Power Monitoring Expert

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

Mar 10, 2026
All Schneider-Electric CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2025-13845 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications