Sources: National Vulnerability Database, CVE.org, CISA KEV, FIRST EPSS
CVE-2025-71457 Overview
vtenext 25.02 before 25.02.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to change any account password via hub/rpwd.php without token verification. Attackers knowing a valid user_name can send action=change_password to RecoverPwd::displayChangePwd() and log in as administrators lacking two-factor authentication.
Critical Impact
Affected Products
- vtenext: see the vendor advisory for the exact affected versions
Discovery Timeline
- 2026-11-04: CVE-2025-71457 published to the National Vulnerability Database by disclosure@vulncheck.com
- 2026-11-04: last updated in the NVD database
Technical Details for CVE-2025-71457
Vulnerability Analysis
CVE-2025-71457 is a Security Vulnerability weakness (CWE-620) in vtenext. Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction.
With a CVSS base score of 9.3, apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Root Cause
The vendor description states: vtenext 25.02 before 25.02.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to change any account password via hub/rpwd.php without token verification. Attackers knowing a valid user_name can send action=change_password to RecoverPwd::displayChangePwd() and log in as administrators lacking two-factor authentication.
Attack Vector
Based on the CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Attack complexity is low complexity.
No exploitation in the wild is confirmed by CISA at the time of the last update. Check the references below for any vendor or researcher proof of concept.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Detection Methods for CVE-2025-71457
Detection Strategies
- Inventory every instance of vtenext and compare the running version with the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Run an authenticated vulnerability scan once your scanner ships a check for this CVE.
Monitoring Recommendations
- Forward vtenext application, access and audit logs to your SIEM for retrospective hunting.
- Alert on new processes, configuration changes or outbound connections from the affected service.
- Track the vendor advisory and the CISA KEV catalog for changes in exploitation status.
How to Mitigate CVE-2025-71457
Immediate Actions Required
- Apply the fixed version of vtenext named in the vendor advisory.
- Prioritize internet facing and business critical instances first.
- Rescan after the change to confirm the exposure is closed.
Patch Information
Use the fixed version listed in the vendor advisory for vtenext.
Workarounds
- If patching must wait, restrict network access to the affected service and place it behind authentication or a web application firewall rule.
CWE References
Technical References
This entry is built directly from NVD, CISA KEV and EPSS data. Verify fixed versions in the vendor advisory before you deploy.
Frequently asked questions
Related CVEs
Unverified password change vulnerability in Vimesoft Inc. Enterprise Video Platform allows Authentication Bypass. This issue affects Enterprise Video Platform: from 3.11.0.0 before 3.25.0.
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.
Flowise before 3.0.10 contains an unverified password change vulnerability. An authenticated user can change their account password through the account settings (Security) section without supplying the current password or any additional verification, as the application does not enforce a current-password check on the credential change. This can lead to full account takeover, particularly if an attacker can hijack or coerce an authenticated session.
EventSentry versions prior to 6.0.1.20 contain an unverified password change vulnerability in the account management functionality of the Web Reports interface. The password change mechanism does not require validation of the current password before allowing a new password to be set. An attacker who gains temporary access to an authenticated user session can change the account password without knowledge of the original credentials. This enables persistent account takeover and, if administrative accounts are affected, may result in privilege escalation.
SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain an authentication vulnerability that allows authenticated users to change account passwords without verifying the current password. Attackers who gain access to an authenticated session can modify credentials to maintain persistent access to the management interface.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2025-71457 with a free CTEM certification.
Beginner / Practitioner / Program Leader