LearnCTEM.com, Best CTEM Learning Platform
CVE Intelligence Hub

CVE-2025-66049: Vivotek Ip7137 Firmware Missing Authentication (CVSS 8.7)

CVE-2025-66049 is a high severity missing authentication in Vivotek Ip7137 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Last updated: Jun 17, 2026

Quick answer

Direct answer

CVE-2025-66049 is a high severity missing authentication in Vivotek Ip7137 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Risk scores

CVSS base score
8.7HIGH
EPSS probability
0.41%
Higher than 34 percent of all CVEs
CISA KEV
Not listed
CVSS metricWhat it means
Attack vector (AV:N)Network: reachable remotely
Attack complexity (AC:L)Low complexity
Attack requirements (AT:N)No attack requirements
Privileges required (PR:N)No privileges required
User interaction (UI:N)No user interaction
Confidentiality (VC:H)High confidentiality impact
Integrity (VI:N)No integrity impact
Availability (VA:N)No availability impact

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

About Vivotek Ip7137 Firmware

CVE-2025-66049 affects Vivotek Ip7137 Firmware, a product from Vivotek. Before acting, confirm where Vivotek Ip7137 Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.

What the flaw is

In plain terms: Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

The weakness class is Missing Authentication. A critical function can be used without logging in.

Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Affected versions and timeline

FieldDetail
ProductVivotek Ip7137 Firmware
Affected versionsIp7137 Firmware 0200a
PublishedJan 9, 2026
Last modifiedJun 17, 2026
Added to CISA KEVNot listed
Assigning CNAcvd@cert.pl

How to detect it

  • Inventory every instance of Vivotek Ip7137 Firmware and record the running version against the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
  • Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.

How to fix it

  • Apply the fixed version of Vivotek Ip7137 Firmware named in the vendor advisory.
  • If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
  • Rescan after the change to prove the exposure is gone, then close the ticket.

CTEM action plan

CTEM stageWhat to do for this CVE
ScopeAdd every business service that depends on Vivotek Ip7137 Firmware to the current CTEM cycle.
DiscoverFind all instances, including shadow and cloud deployments, and record versions and exposure.
PrioritizeRank using EPSS and CVSS together with asset exposure and business impact.
ValidateConfirm the flaw is reachable and exploitable in your environment and that compensating controls work.
MobilizeAssign the fix to the asset owner with a due date matched to the priority, then verify closure.

CWE References

Technical References

Frequently asked questions

CVE-2025-66049 is a high severity missing authentication in Vivotek Ip7137 Firmware with a CVSS score of 8.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

HIGH8.8
CVE-2026-30652
Vivotek Fd8136 Firmware

A remote buffer overflow vulnerability exists in the /cgi-bin/dido/setdo.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device.

Jun 2, 2026
HIGH8.6
CVE-2025-66052
Vivotek Ip7137 Firmware

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Jan 9, 2026
CRITICAL9.3
CVE-2025-66050
Vivotek Ip7137 Firmware

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Jan 9, 2026
CRITICAL10.0
CVE-2026-34162
Fastgpt

FastGPT is an AI Agent building platform. Prior to version 4.14.9.5, the FastGPT HTTP tools testing endpoint (/api/core/app/httpTools/runTool) is exposed without any authentication. This endpoint acts as a full HTTP proxy — it accepts a user-supplied baseUrl, toolPath, HTTP method, custom headers, and body, then makes a server-side HTTP request and returns the complete response to the caller. This issue has been patched in version 4.14.9.5.

Mar 31, 2026
CRITICAL10.0
CVE-2026-3611
Honeywell Iq4e Firmware

The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.

Mar 12, 2026
CRITICAL10.0
CVE-2026-25885
Polarlearn

PolarLearn is a free and open-source learning program. In 0-PRERELEASE-16 and earlier, the group chat WebSocket at wss://polarlearn.nl/api/v1/ws can be used without logging in. An unauthenticated client can subscribe to any group chat by providing a group UUID, and can also send messages to any group. The server accepts the message and stores it in the group’s chatContent, so this is not just a visual spam issue.

Feb 9, 2026
All Vivotek CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2025-66049 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications