Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:L) | Local access needed |
| Attack complexity (AC:L) | Low complexity |
| Attack requirements (AT:N) | No attack requirements |
| Privileges required (PR:N) | No privileges required |
| User interaction (UI:N) | No user interaction |
| Confidentiality (VC:H) | High confidentiality impact |
| Integrity (VI:H) | High integrity impact |
| Availability (VA:H) | High availability impact |
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
About Draeger Infinity Explorer C700 Firmware
CVE-2019-25718 affects Draeger Infinity Explorer C700 Firmware, a product from Draeger. Before acting, confirm where Draeger Infinity Explorer C700 Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.
Based on its CVSS vector, the flaw needs local or adjacent access, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Draeger Infinity Explorer C700 Firmware |
| Affected versions | Infinity Explorer C700 Firmware all listed versions |
| Published | Jun 1, 2026 |
| Last modified | Jul 22, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | disclosure@vulncheck.com |
How to detect it
- Inventory every instance of Draeger Infinity Explorer C700 Firmware and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Draeger Infinity Explorer C700 Firmware named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Draeger Infinity Explorer C700 Firmware to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
Technical References
Frequently asked questions
Related CVEs
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.
Malicious scripts could cause desynchronization between the address bar and web content before a response is received in Firefox iOS, allowing attacker-controlled pages to be presented under spoofed domains. This vulnerability was fixed in Firefox for iOS 147.4.
better-auth from 1.3.8-beta.3 before 1.7.0-rc.3 contains a UI misrepresentation vulnerability in the deviceAuthorization plugin because GET /device omits the requesting client_id and scope. Attackers can start a device request via /device/code, trick signed-in users into approving the code, then redeem it at /device/token for a live session token.
OpenClaw before 2026.3.11 contains an approval-integrity vulnerability in node-host system.run approvals that displays extracted shell payloads instead of the executed argv. Attackers can place wrapper binaries and induce wrapper-shaped commands to execute local code after operators approve misleading command text.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2019-25718 with a free CTEM certification.
Beginner / Practitioner / Program Leader
Explore certifications