Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:L) | Local access needed |
| Attack complexity (AC:L) | Low complexity |
| Attack requirements (AT:N) | No attack requirements |
| Privileges required (PR:L) | Low privileges required |
| User interaction (UI:N) | No user interaction |
| Confidentiality (VC:H) | High confidentiality impact |
| Integrity (VI:H) | High integrity impact |
| Availability (VA:H) | High availability impact |
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
About Hitachienergy Microscada X Sys600
CVE-2026-9853 affects Hitachienergy Microscada X Sys600, a product from Hitachienergy. Before acting, confirm where Hitachienergy Microscada X Sys600 runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself. Only the SYS600 system users should be permitted to view and modify application objects.
Based on its CVSS vector, the flaw needs local or adjacent access, needs some level of access, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Hitachienergy Microscada X Sys600 |
| Affected versions | Microscada X Sys600 from 10.0 up to and including 10.8 |
| Published | Sep 3, 2026 |
| Last modified | Sep 9, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | cybersecurity@hitachienergy.com |
How to detect it
- Inventory every instance of Hitachienergy Microscada X Sys600 and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Hitachienergy Microscada X Sys600 named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Hitachienergy Microscada X Sys600 to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
Technical References
Frequently asked questions
Related CVEs
A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine.
A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so.
A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so.
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.
UDS Identity Config builds the Keycloak configuration image (realm, plugins, theme, truststore, JARs) consumed by UDS Core's Identity deployment. In versions 0.11.0 through 0.26.0, a logic error in the `client-kubernetes-secret` Keycloak client authenticator (shipped by `uds-identity-config` and consumed by UDS Core) causes the submitted `client_secret` to be overwritten with the mounted Kubernetes secret before comparison. An attacker who can reach the Keycloak token endpoint and knows a `client_id` using this authenticator can authenticate as that client with any `client_secret` value and obtain OAuth2 tokens scoped to the client's service account. In the case of the `uds-operator` client this token can be used to registry/modify other clients. Version 0.26.1 patches the issue.
MiCode FileExplorer contains an authentication bypass vulnerability in the embedded SwiFTP FTP server component that allows network attackers to log in without valid credentials. Attackers can send arbitrary username and password combinations to the PASS command handler, which unconditionally grants access and allows listing, reading, writing, and deleting files exposed by the FTP server. The MiCode/Explorer open source project has reached end-of-life status.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-9853 with a free CTEM certification.
Beginner / Practitioner / Program Leader