CVE-2026-87666: Broadcom Fabric Operating System OS Command Injection (CVSS 8.6)

CVE-2026-87666 is a high severity os command injection in Broadcom Fabric Operating System with a CVSS score of 8.6. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Last updated: Oct 14, 2026

Quick answer

Direct answer

CVE-2026-87666 is a high severity os command injection in Broadcom Fabric Operating System with a CVSS score of 8.6. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Risk scores

CVSS base score
8.6HIGH
EPSS probability
1.85%
Higher than 79 percent of all CVEs
CISA KEV
Not listed
CVSS metricWhat it means
Attack vector (AV:A)Adjacent network
Attack complexity (AC:L)Low complexity
Attack requirements (AT:N)No attack requirements
Privileges required (PR:L)Low privileges required
User interaction (UI:N)No user interaction
Confidentiality (VC:H)High confidentiality impact
Integrity (VI:H)High integrity impact
Availability (VA:H)High availability impact

CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

About Broadcom Fabric Operating System

CVE-2026-87666 affects Broadcom Fabric Operating System, a product from Broadcom. Before acting, confirm where Broadcom Fabric Operating System runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.

What the flaw is

In plain terms: An OS command injection vulnerability exists in the time and zone management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When updating system timezone settings via the REST API or configuration download routines, the system fails to sanitize input values before processing them in underlying shell execution routines. An authenticated user with low-privilege administrative access can exploit this vulnerability by submitting a crafted timezone string containing shell metacharacters. Successful exploitation allows the attacker to escape the restricted management environment and execute arbitrary shell commands with elevated privileges.

The weakness class is OS Command Injection. Untrusted input is passed to the operating system shell, letting an attacker run commands.

Based on its CVSS vector, the flaw needs local or adjacent access, needs some level of access, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Affected versions and timeline

FieldDetail
ProductBroadcom Fabric Operating System
Affected versionsFabric Operating System before 9.2.2d; Fabric Operating System from 10.0.0 before 10.0.1
PublishedOct 8, 2026
Last modifiedOct 14, 2026
Added to CISA KEVNot listed
Assigning CNAsirt@brocade.com

How to detect it

  • Inventory every instance of Broadcom Fabric Operating System and record the running version against the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
  • Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.

How to fix it

  • Apply the fixed version of Broadcom Fabric Operating System named in the vendor advisory.
  • If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
  • Rescan after the change to prove the exposure is gone, then close the ticket.

CTEM action plan

CTEM stageWhat to do for this CVE
ScopeAdd every business service that depends on Broadcom Fabric Operating System to the current CTEM cycle.
DiscoverFind all instances, including shadow and cloud deployments, and record versions and exposure.
PrioritizeRank using EPSS and CVSS together with asset exposure and business impact.
ValidateConfirm the flaw is reachable and exploitable in your environment and that compensating controls work.
MobilizeAssign the fix to the asset owner with a due date matched to the priority, then verify closure.

CWE References

Technical References

Frequently asked questions

CVE-2026-87666 is a high severity os command injection in Broadcom Fabric Operating System with a CVSS score of 8.6. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

HIGH8.4
CVE-2026-87428
Broadcom Brocade Active Support Connectivity Gateway

In Brocade ASCG before 3.5.0, a  local unauthorized user on the ASCG VM who can issue a request to the SANnav host network namespace can extract stored management credentials for onboarded SANnav instances and compromise connected Brocade SANnav servers or managed Brocade Fibre Channel switches.

Oct 8, 2026
HIGH8.6
CVE-2026-87424
Broadcom Brocade Active Support Connectivity Gateway

A vulnerability in the SupportLink API authentication component of Brocade ASCG versions prior to 3.5.0 allows an attacker to bypass authentication across deployments due to the use of a hard coded cryptographic key.

Oct 8, 2026
HIGH7.7
CVE-2026-85490
Broadcom Brocade Active Support Connectivity Gateway

When Brocade ASCG before 3.5.0 processes support bundle archives ingested from remote compromised endpoints, the application fails to sanitize path traversal sequences contained within archive entries prior to extraction. An unauthenticated remote attacker capable of sending or intercepting ingested archive files can leverage this flaw to write arbitrary files to restricted locations on the underlying host, potentially leading to remote code execution.

Oct 8, 2026
HIGH8.7
CVE-2026-85489
Broadcom Brocade Active Support Connectivity Gateway

An authentication flaw exists in the Brocade ASCG administrative management service component. An unauthenticated network user can issue direct API requests to perform privileged actions, including accessing sensitive system configuration mapping data, modifying managed device inventories, and altering operational settings. This vulnerability affects all versions of Brocade ASCG before 3.5.0.

Oct 8, 2026
HIGH7.0
CVE-2026-85488
Broadcom Brocade Active Support Connectivity Gateway

Brocade ASCG before 3.5.0 has a well-known Brocade default password embedded in a script distributed to every customer. Any local authenticated user with read access to the installation path can discover this credential and perform privilege escalation on affected Open Virtual Appliance (OVA) deployments, where default configuration settings remain in place.

Oct 8, 2026
HIGH8.6
CVE-2026-85487
Broadcom Brocade Active Support Connectivity Gateway

A path traversal vulnerability exists in the HTTP service component of Brocade ASCG versions before 3.5.0. An unauthenticated attacker on the local network could send a manipulated API request to the service endpoint bypassing path restrictions to arbitrary file read, file write, or file deletion operations.

Oct 8, 2026
All Broadcom CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-87666 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications