Sources: National Vulnerability Database, CVE.org, CISA KEV, FIRST EPSS
CVE-2026-60044 Overview
The backups created by the application use a weak static password allowing an unauthenticated remote attacker to access their content. This can result in a total loss of confidentiality.
Critical Impact
Affected Products
- Product named in vendor advisory: see the vendor advisory for the exact affected versions
Discovery Timeline
- 2026-11-10: CVE-2026-60044 published to the National Vulnerability Database by info@cert.vde.com
- 2026-11-10: last updated in the NVD database
Technical Details for CVE-2026-60044
Vulnerability Analysis
CVE-2026-60044 is a Security Vulnerability weakness (CWE-1393) in Product named in vendor advisory. Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction.
With a CVSS base score of 8.7, apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Root Cause
The vendor description states: The backups created by the application use a weak static password allowing an unauthenticated remote attacker to access their content. This can result in a total loss of confidentiality.
Attack Vector
Based on the CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Attack complexity is low complexity.
No exploitation in the wild is confirmed by CISA at the time of the last update. Check the references below for any vendor or researcher proof of concept.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Detection Methods for CVE-2026-60044
Detection Strategies
- Inventory every instance of Product named in vendor advisory and compare the running version with the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Run an authenticated vulnerability scan once your scanner ships a check for this CVE.
Monitoring Recommendations
- Forward Product named in vendor advisory application, access and audit logs to your SIEM for retrospective hunting.
- Alert on new processes, configuration changes or outbound connections from the affected service.
- Track the vendor advisory and the CISA KEV catalog for changes in exploitation status.
How to Mitigate CVE-2026-60044
Immediate Actions Required
- Apply the fixed version of Product named in vendor advisory named in the vendor advisory.
- Prioritize internet facing and business critical instances first.
- Rescan after the change to confirm the exposure is closed.
Patch Information
Use the fixed version listed in the vendor advisory for Product named in vendor advisory.
Workarounds
- If patching must wait, restrict network access to the affected service and place it behind authentication or a web application firewall rule.
CWE References
Technical References
This entry is built directly from NVD, CISA KEV and EPSS data. Verify fixed versions in the vendor advisory before you deploy.
Frequently asked questions
Related CVEs
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-60044 with a free CTEM certification.
Beginner / Practitioner / Program Leader