CVE-2026-58114: Siemens SIMATIC BATCH Security Vulnerability

CVE-2026-58114 explained: high Security Vulnerability in Siemens SIMATIC BATCH. CVSS 7.7. Affected versions, detection, fixes and CTEM priority.

Last updated: Nov 10, 2026

CVSS
7.7 HIGH
EPSS
n/a
CISA KEV
Not listed
CWE
CWE-1390

Sources: National Vulnerability Database, CVE.org, CISA KEV, FIRST EPSS

CVE-2026-58114 Overview

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

Critical Impact

Remote, unauthenticated attackers who persuade a user to act can exploit this Security Vulnerability in Siemens SIMATIC BATCH. The CVSS base score is 7.7 (High).

Affected Products

  • Siemens SIMATIC BATCH: see the vendor advisory for the exact affected versions

Discovery Timeline

  • 2026-11-10: CVE-2026-58114 published to the National Vulnerability Database by productcert@siemens.com
  • 2026-11-10: last updated in the NVD database

Technical Details for CVE-2026-58114

Vulnerability Analysis

CVE-2026-58114 is a Security Vulnerability weakness (CWE-1390) in Siemens SIMATIC BATCH. Based on its CVSS vector, the flaw can be reached over the network, needs no login, and relies on a user taking an action.

With a CVSS base score of 7.7, apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Root Cause

The vendor description states: A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

Attack Vector

Based on the CVSS vector, the flaw can be reached over the network, needs no login, and relies on a user taking an action. Attack complexity is low complexity.

No exploitation in the wild is confirmed by CISA at the time of the last update. Check the references below for any vendor or researcher proof of concept.

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Detection Methods for CVE-2026-58114

Detection Strategies

  • Inventory every instance of Siemens SIMATIC BATCH and compare the running version with the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Run an authenticated vulnerability scan once your scanner ships a check for this CVE.

Monitoring Recommendations

  • Forward Siemens SIMATIC BATCH application, access and audit logs to your SIEM for retrospective hunting.
  • Alert on new processes, configuration changes or outbound connections from the affected service.
  • Track the vendor advisory and the CISA KEV catalog for changes in exploitation status.

How to Mitigate CVE-2026-58114

Immediate Actions Required

  • Apply the fixed version of Siemens SIMATIC BATCH named in the vendor advisory.
  • Prioritize internet facing and business critical instances first.
  • Rescan after the change to confirm the exposure is closed.

Patch Information

Use the fixed version listed in the vendor advisory for Siemens SIMATIC BATCH.

Workarounds

  • If patching must wait, restrict network access to the affected service and place it behind authentication or a web application firewall rule.

CWE References

Technical References

This entry is built directly from NVD, CISA KEV and EPSS data. Verify fixed versions in the vendor advisory before you deploy.

Frequently asked questions

CVE-2026-58114 is a high severity Security Vulnerability in Siemens SIMATIC BATCH with a CVSS score of 7.7. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

HIGH8.5
CVE-2026-59082
Siemens SIMATIC WinCC

A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.

Nov 10, 2026
CRITICAL9.2
CVE-2026-112136
Siemens Mendix Studio Pro

A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.

Nov 10, 2026
HIGH7.0
CVE-2026-109830
Siemens meta-iot2050

A vulnerability has been identified in meta-iot2050 (All versions >= V01.03.01). Affected devices take parts from a configuration file and execute them unchecked. This could allow an attacker which is able to manipulate the configuration file to make the user execute arbitrary code on the device.

Nov 10, 2026
HIGH8.6
CVE-2026-109097
Siemens ROS#

A vulnerability has been identified in ROS# (All versions < V2.3.1). Affected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program.

Nov 10, 2026
HIGH8.7
CVE-2026-46748
Siemens Sinec Ins

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system.

Jun 9, 2026
HIGH8.6
CVE-2026-25573
Siemens Sicam Siapp Sdk

A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise.

Mar 10, 2026
All Siemens CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-58114 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader