LearnCTEM.com, Best CTEM Learning Platform
CVE Intelligence Hub

CVE-2026-49197: Acer Predator Connect W6x Firmware Improper Authentication (CVSS 10)

CVE-2026-49197 is a critical severity improper authentication in Acer Predator Connect W6x Firmware with a CVSS score of 10. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Last updated: Jul 21, 2026

Quick answer

Direct answer

CVE-2026-49197 is a critical severity improper authentication in Acer Predator Connect W6x Firmware with a CVSS score of 10. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Risk scores

CVSS base score
10CRITICAL
EPSS probability
0.53%
Higher than 43 percent of all CVEs
CISA KEV
Not listed
CVSS metricWhat it means
Attack vector (AV:N)Network: reachable remotely
Attack complexity (AC:L)Low complexity
Attack requirements (AT:N)No attack requirements
Privileges required (PR:N)No privileges required
User interaction (UI:N)No user interaction
Confidentiality (VC:H)High confidentiality impact
Integrity (VI:H)High integrity impact
Availability (VA:H)High availability impact

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

About Acer Predator Connect W6x Firmware

CVE-2026-49197 affects Acer Predator Connect W6x Firmware, a product from Acer. Before acting, confirm where Acer Predator Connect W6x Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.

What the flaw is

In plain terms: Web endpoints intended for the Acer Connect app improperly validate the HTTP Authorization header, failing to block requests when Base64 decoding fails.

The weakness class is Improper Authentication. The software does not properly prove who a user is.

Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Affected versions and timeline

FieldDetail
ProductAcer Predator Connect W6x Firmware
Affected versionsPredator Connect W6x Firmware up to and including w6x_gbl_2.00.000005
PublishedMay 29, 2026
Last modifiedJul 21, 2026
Added to CISA KEVNot listed
Assigning CNA8fc372e3-d9c5-46e4-9410-38469745c639

How to detect it

  • Inventory every instance of Acer Predator Connect W6x Firmware and record the running version against the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
  • Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.

How to fix it

  • Apply the fixed version of Acer Predator Connect W6x Firmware named in the vendor advisory.
  • If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
  • Rescan after the change to prove the exposure is gone, then close the ticket.

CTEM action plan

CTEM stageWhat to do for this CVE
ScopeAdd every business service that depends on Acer Predator Connect W6x Firmware to the current CTEM cycle.
DiscoverFind all instances, including shadow and cloud deployments, and record versions and exposure.
PrioritizeRank using EPSS and CVSS together with asset exposure and business impact.
ValidateConfirm the flaw is reachable and exploitable in your environment and that compensating controls work.
MobilizeAssign the fix to the asset owner with a due date matched to the priority, then verify closure.

CWE References

Technical References

Frequently asked questions

CVE-2026-49197 is a critical severity improper authentication in Acer Predator Connect W6x Firmware with a CVSS score of 10. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

All Acer CVEs in 2026
Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-49197 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications