Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:N) | Network: reachable remotely |
| Attack complexity (AC:L) | Low complexity |
| Attack requirements (AT:N) | No attack requirements |
| Privileges required (PR:L) | Low privileges required |
| User interaction (UI:N) | No user interaction |
| Confidentiality (VC:H) | High confidentiality impact |
| Integrity (VI:H) | High integrity impact |
| Availability (VA:H) | High availability impact |
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
About Tenda F453 Firmware
CVE-2026-3271 affects Tenda F453 Firmware, a product from Tenda. Before acting, confirm where Tenda F453 Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: A vulnerability was found in Tenda F453 1.0.0.3. This impacts the function fromP2pListFilter of the file /goform/P2pListFilterof of the component httpd. The manipulation of the argument page results in buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
The weakness class is Memory Buffer Errors. The program reads or writes outside the memory it should.
Based on its CVSS vector, the flaw can be reached over the network, needs some level of access, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Tenda F453 Firmware |
| Affected versions | F453 Firmware 1.0.0.3 |
| Published | Feb 27, 2026 |
| Last modified | Jun 17, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | cna@vuldb.com |
How to detect it
- Inventory every instance of Tenda F453 Firmware and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Tenda F453 Firmware named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Tenda F453 Firmware to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
- CWE-119: Memory Buffer Errors More CVEs with this weakness
- CWE-120: Classic Buffer Overflow More CVEs with this weakness
- CWE-120: Classic Buffer Overflow More CVEs with this weakness
Technical References
Frequently asked questions
Related CVEs
In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can lead to remote arbitrary code execution.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the wanMTU parameter.
A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.
Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetCfm function via the funcname, funcpara1, and funcpara2 parameters.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-3271 with a free CTEM certification.
Beginner / Practitioner / Program Leader
Explore certifications