Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:N) | Network: reachable remotely |
| Attack complexity (AC:L) | Low complexity |
| Privileges required (PR:N) | No privileges required |
| User interaction (UI:N) | No user interaction |
| Scope (S:U) | Scope unchanged |
| Confidentiality (C:H) | High confidentiality impact |
| Integrity (I:H) | High integrity impact |
| Availability (A:H) | High availability impact |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
About Tenda W20e Firmware
CVE-2026-24113 affects Tenda W20e Firmware, a product from Tenda. Before acting, confirm where Tenda W20e Firmware runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by controlling the value of `nptr`. When this value is passed into the `getMibPrefix` function and concatenated using `sprintf` without proper size validation, it could lead to a buffer overflow vulnerability.
The weakness class is Classic Buffer Overflow. Data is copied into a buffer without checking its size.
Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Tenda W20e Firmware |
| Affected versions | W20e Firmware 15.11.0.6 |
| Published | Mar 2, 2026 |
| Last modified | Jun 17, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | cve@mitre.org |
How to detect it
- Inventory every instance of Tenda W20e Firmware and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Tenda W20e Firmware named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Tenda W20e Firmware to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
- CWE-120: Classic Buffer Overflow More CVEs with this weakness
- CWE-120: Classic Buffer Overflow More CVEs with this weakness
Technical References
Frequently asked questions
Related CVEs
In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can lead to remote arbitrary code execution.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the wanMTU parameter.
A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.
Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetCfm function via the funcname, funcpara1, and funcpara2 parameters.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-24113 with a free CTEM certification.
Beginner / Practitioner / Program Leader