Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:L) | Local access needed |
| Attack complexity (AC:H) | High complexity |
| Attack requirements (AT:N) | No attack requirements |
| Privileges required (PR:N) | No privileges required |
| User interaction (UI:P) | Passive user interaction |
| Confidentiality (VC:H) | High confidentiality impact |
| Integrity (VI:H) | High integrity impact |
| Availability (VA:H) | High availability impact |
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
About Siemens Simcenter Femap
CVE-2026-23716 affects Siemens Simcenter Femap, a product from Siemens. Before acting, confirm where Siemens Simcenter Femap runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
The weakness class is Out of Bounds Read. The program reads memory past the end of a buffer, leaking data or crashing.
Based on its CVSS vector, the flaw needs local or adjacent access, needs no login, and relies on a user taking an action. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Siemens Simcenter Femap |
| Affected versions | Simcenter Femap before 2512.0000; Simcenter Nastran before 2512.0000 |
| Published | Feb 10, 2026 |
| Last modified | Jun 17, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | productcert@siemens.com |
How to detect it
- Inventory every instance of Siemens Simcenter Femap and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Siemens Simcenter Femap named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Siemens Simcenter Femap to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
- CWE-125: Out of Bounds Read More CVEs with this weakness
Technical References
Frequently asked questions
Related CVEs
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service.
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-23716 with a free CTEM certification.
Beginner / Practitioner / Program Leader