LearnCTEM.com, Best CTEM Learning Platform
CVE Intelligence Hub

CVE-2026-129250: Edimax BR6478ACV2 Memory Buffer Errors Vulnerability

CVE-2026-129250 explained: high Memory Buffer Errors in Edimax BR6478ACV2. CVSS 8.6. Affected versions, detection, fixes and CTEM priority.

Last updated: Nov 14, 2026

CVSS
8.6 HIGH
EPSS
n/a
CISA KEV
Not listed
CWE
CWE-119

Sources: National Vulnerability Database, CVE.org, CISA KEV, FIRST EPSS

CVE-2026-129250 Overview

A security vulnerability has been detected in Edimax BR6478ACV2 1.23. The impacted element is the function formPPTPSetup of the file webs. The manipulation of the argument pptpUserName leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Critical Impact

Remote, authenticated attackers can exploit this Memory Buffer Errors in Edimax BR6478ACV2. The CVSS base score is 8.6 (High).

Affected Products

  • Edimax BR6478ACV2: see the vendor advisory for the exact affected versions

Discovery Timeline

  • 2026-11-14: CVE-2026-129250 published to the National Vulnerability Database by cna@vuldb.com
  • 2026-11-14: last updated in the NVD database

Technical Details for CVE-2026-129250

Vulnerability Analysis

CVE-2026-129250 is a Memory Buffer Errors weakness (CWE-119: Memory Buffer Errors, CWE-120: Classic Buffer Overflow) in Edimax BR6478ACV2. Based on its CVSS vector, the flaw can be reached over the network, needs some level of access, and needs no user interaction. The program reads or writes outside the memory it should.

With a CVSS base score of 8.6, apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Root Cause

The weakness is classified as CWE-119: Memory Buffer Errors, CWE-120: Classic Buffer Overflow. The program reads or writes outside the memory it should.

Attack Vector

Based on the CVSS vector, the flaw can be reached over the network, needs some level of access, and needs no user interaction. Attack complexity is low complexity.

No exploitation in the wild is confirmed by CISA at the time of the last update. Check the references below for any vendor or researcher proof of concept.

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Detection Methods for CVE-2026-129250

Detection Strategies

  • Inventory every instance of Edimax BR6478ACV2 and compare the running version with the affected range above.
  • Check external attack surface scans for internet facing instances of the component.
  • Run an authenticated vulnerability scan once your scanner ships a check for this CVE.

Monitoring Recommendations

  • Forward Edimax BR6478ACV2 application, access and audit logs to your SIEM for retrospective hunting.
  • Alert on new processes, configuration changes or outbound connections from the affected service.
  • Track the vendor advisory and the CISA KEV catalog for changes in exploitation status.

How to Mitigate CVE-2026-129250

Immediate Actions Required

  • Apply the fixed version of Edimax BR6478ACV2 named in the vendor advisory.
  • Prioritize internet facing and business critical instances first.
  • Rescan after the change to confirm the exposure is closed.

Patch Information

Use the fixed version listed in the vendor advisory for Edimax BR6478ACV2.

Workarounds

  • If patching must wait, restrict network access to the affected service and place it behind authentication or a web application firewall rule.

CWE References

Technical References

This entry is built directly from NVD, CISA KEV and EPSS data. Verify fixed versions in the vendor advisory before you deploy.

Frequently asked questions

CVE-2026-129250 is a high severity Memory Buffer Errors in Edimax BR6478ACV2 with a CVSS score of 8.6. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.

Related CVEs

Your next credential

Earn your free CTEM certification.

Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-129250 with a free CTEM certification.

Free to takePublicly verifiable

Beginner / Practitioner / Program Leader

Explore certifications