Sources: National Vulnerability Database, CVE.org, CISA KEV, FIRST EPSS
CVE-2026-129167 Overview
Seafile SeaDoc converter 2.0.4 before 2.0.11 and 3.0.0 before 3.0.8 contains an absolute path traversal vulnerability that allows unauthenticated attackers holding a public share token to execute code. Attackers supply an absolute filename to /api/v1/confluence-to-wiki/ to extract a ZIP from download_url into the Python library path, then trigger the module's import via a file-convert request.
Critical Impact
Affected Products
- Seafile SeaDoc converter: see the vendor advisory for the exact affected versions
Discovery Timeline
- 2026-11-13: CVE-2026-129167 published to the National Vulnerability Database by disclosure@vulncheck.com
- 2026-11-13: last updated in the NVD database
Technical Details for CVE-2026-129167
Vulnerability Analysis
CVE-2026-129167 is a Security Vulnerability weakness (CWE-36) in Seafile SeaDoc converter. Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction.
With a CVSS base score of 9.2, apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Root Cause
The vendor description states: Seafile SeaDoc converter 2.0.4 before 2.0.11 and 3.0.0 before 3.0.8 contains an absolute path traversal vulnerability that allows unauthenticated attackers holding a public share token to execute code. Attackers supply an absolute filename to /api/v1/confluence-to-wiki/ to extract a ZIP from download_url into the Python library path, then trigger the module's import via a file-convert request.
Attack Vector
Based on the CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Attack complexity is high complexity.
No exploitation in the wild is confirmed by CISA at the time of the last update. Check the references below for any vendor or researcher proof of concept.
CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Detection Methods for CVE-2026-129167
Detection Strategies
- Inventory every instance of Seafile SeaDoc converter and compare the running version with the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Run an authenticated vulnerability scan once your scanner ships a check for this CVE.
Monitoring Recommendations
- Forward Seafile SeaDoc converter application, access and audit logs to your SIEM for retrospective hunting.
- Alert on new processes, configuration changes or outbound connections from the affected service.
- Track the vendor advisory and the CISA KEV catalog for changes in exploitation status.
How to Mitigate CVE-2026-129167
Immediate Actions Required
- Apply the fixed version of Seafile SeaDoc converter named in the vendor advisory.
- Prioritize internet facing and business critical instances first.
- Rescan after the change to confirm the exposure is closed.
Patch Information
Use the fixed version listed in the vendor advisory for Seafile SeaDoc converter.
Workarounds
- If patching must wait, restrict network access to the affected service and place it behind authentication or a web application firewall rule.
CWE References
Technical References
This entry is built directly from NVD, CISA KEV and EPSS data. Verify fixed versions in the vendor advisory before you deploy.
Frequently asked questions
Related CVEs
IBM DataStage on Cloud Pak for Data 5.4.0.0 could allow a remote authenticated attacker to obtain sensitive information due to an absolute-path traversal vulnerability.
MindsDB is a platform for building artificial intelligence from enterprise data. Prior to version 25.11.1, an unauthenticated path traversal in the file upload API lets any caller read arbitrary files from the server filesystem and move them into MindsDB’s storage, exposing sensitive data. The PUT handler in file.py directly joins user-controlled data into a filesystem path when the request body is JSON and source_type is not "url". Only multipart uploads and URL-sourced uploads receive sanitization; JSON uploads lack any call to clear_filename or equivalent checks. This vulnerability is fixed in 25.11.1.
Absolute path traversal in Microsoft Windows Search Component allows an authorized attacker to elevate privileges locally.
A vulnerability in the `filestring()` function of the `nltk.util` module in nltk version 3.9.2 allows arbitrary file read due to improper validation of input paths. The function directly opens files specified by user input without sanitization, enabling attackers to access sensitive system files by providing absolute paths or traversal paths. This vulnerability can be exploited locally or remotely, particularly in scenarios where the function is used in web APIs or other interfaces that accept user-supplied input.
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2026-129167 with a free CTEM certification.
Beginner / Practitioner / Program Leader