Quick answer
Direct answer
Risk scores
| CVSS metric | What it means |
|---|---|
| Attack vector (AV:N) | Network: reachable remotely |
| Attack complexity (AC:L) | Low complexity |
| Attack requirements (AT:N) | No attack requirements |
| Privileges required (PR:N) | No privileges required |
| User interaction (UI:N) | No user interaction |
| Confidentiality (VC:N) | No confidentiality impact |
| Integrity (VI:N) | No integrity impact |
| Availability (VA:N) | No availability impact |
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:X/R:X/V:X/RE:X/U:X
About Nuvationenergy Nplatform
CVE-2025-64123 affects Nuvationenergy Nplatform, a product from Nuvationenergy. Before acting, confirm where Nuvationenergy Nplatform runs in your estate, who owns it and whether it is reachable from the internet, because exposure decides real risk more than the score alone.
What the flaw is
In plain terms: Unintended Proxy or Intermediary vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Network Boundary Bridging.This issue affects Multi-Stack Controller (MSC): through and including release 2.5.1.
Based on its CVSS vector, the flaw can be reached over the network, needs no login, and needs no user interaction. Apply the vendor fix and confirm exposure on internet facing and business critical assets first.
Affected versions and timeline
| Field | Detail |
|---|---|
| Product | Nuvationenergy Nplatform |
| Affected versions | Nplatform up to and including 2.5.1 |
| Published | Jan 2, 2026 |
| Last modified | Oct 7, 2026 |
| Added to CISA KEV | Not listed |
| Assigning CNA | ot-cert@dragos.com |
How to detect it
- Inventory every instance of Nuvationenergy Nplatform and record the running version against the affected range above.
- Check external attack surface scans for internet facing instances of the component.
- Review logs on affected systems for unusual requests, errors or new processes around the vulnerable function.
- Confirm with an authenticated vulnerability scan once your scanner has a check for this CVE.
How to fix it
- Apply the fixed version of Nuvationenergy Nplatform named in the vendor advisory.
- If patching must wait, restrict network access to the affected service and put it behind authentication or a web application firewall rule.
- Rescan after the change to prove the exposure is gone, then close the ticket.
CTEM action plan
| CTEM stage | What to do for this CVE |
|---|---|
| Scope | Add every business service that depends on Nuvationenergy Nplatform to the current CTEM cycle. |
| Discover | Find all instances, including shadow and cloud deployments, and record versions and exposure. |
| Prioritize | Rank using EPSS and CVSS together with asset exposure and business impact. |
| Validate | Confirm the flaw is reachable and exploitable in your environment and that compensating controls work. |
| Mobilize | Assign the fix to the asset owner with a due date matched to the priority, then verify closure. |
CWE References
Technical References
Frequently asked questions
Related CVEs
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): before 2.5.1.
Authentication Bypass Using an Alternate Path or Channel vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Authentication Bypass.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
Azure Arc Elevation of Privilege Vulnerability
Impact: @fastify/reply-from versions from 8.3.1 up to but not including 12.6.4 build the internal URL cache key by concatenating the destination and source path without a delimiter. Different destination and source pairs can therefore produce the same key while resolving to different upstream URLs. When getUpstream selects an upstream from request data, a URL cached for one upstream can be reused for a request intended for another upstream, causing cross-upstream data access and modification. The default configuration is affected. Setting disableCache to true prevents the behavior. Patches: upgrade to @fastify/reply-from 12.6.4. Workarounds: pass disableCache: true when registering the plugin.
Confused deputy in WebAPKs in Google Chrome on on Android prior to 155.0.8059.39 allowed a remote attacker leveraging social engineering to bypass web origin policy via a crafted HTML page. (Chromium security severity: Low)
Earn your free CTEM certification.
Learn to scope, prioritize, validate and mobilize fixes for CVEs like CVE-2025-64123 with a free CTEM certification.
Beginner / Practitioner / Program Leader
Explore certifications